Belshaw Brothers 616BT Operator's Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
Belshaw Bros., Inc. www.belshaw.com Phone 206-322-5474 Fax 206-322-5425
616B & 616BT TS MN-1138EN 7
Testing the Continuity of
the Thermostat
WARNING
To avoid the possibility of electric shock,
disconnect the machine from the power
source before testing.
1. Disconnect the machine from the power
supply.
2. Disconnect the terminal wires from the
thermostat.
3. Connect the continuity tester across the B
terminals indicated in Figure 4-2. This set of
contacts should be closed whenever the
thermostat is on. To test, start with the
thermostat in the OFF position. Then turn
the thermostat up until you hear a distinct
click (at about the 175°F/79°C setting). At
this time, there should be continuity across
the B terminals.
4. Connect the continuity tester across the A
terminals indicated in Figure B-2. Start with
the thermostat in the OFF position and turn
the thermostat up until you hear a distinct
click. If there is no continuity (the indicator
or light does not come on), proceed to
step 5.
5. With the continuity tester still connected,
turn the thermostat knob to OFF and remove
the knob. There is an adjusting screw in the
center of the knob stem. Turn it counter-
clockwise until there is continuity. If there
is no continuity (the indicator or light does
not come on), then the thermostat is
defective. If there is continuity, proceed to
step 6.
6. Immerse the thermostat sensing bulb in a
pan of boiling water and set the thermostat at
about 212°F/100°C. The continuity tester’s
indicator or light should go off. If the indicator
or light does not go off, increase the temperature
setting of the thermostat until it does. Then
recalibrate the thermostat according to the
manufacturer’s instructions. If the indicator or
light will not go off at any setting or
recalibration, then the thermostat is defective.